| Applications | These cables are mainly used as a flexible feeder for shuttle cars and pump. Earth cores designed to reduce instances of wire breaks during reeling while under tension. |
| Standards | AS/NZS 1802:2003 AS/NZS 1125 AS/NZS 3808 AS/NZS 5000.1 |
| Construction | |
| 3×Conductors | Flexible stranded tinned annealed copper conductor. |
| Insulation | EPR. |
| Cradle Separator | Semiconductive PCP. |
| Overall Core Screen | Semiconductive PCP filling and covering. |
| 3×Interstitial Earth Conductor | Semiconductive PCP covered flexible stranded tinned copper conductor. |
| 1×Central Extensible Pilot | EPR covered flexible stranded tinned copper conductor. |
| Textile Reinforcement | Open-weave braid reinforcement. |
| Sheath | Heavy duty PCP sheath. Heavy duty CPE/CSP sheath can be offered upon request. |
Dimensions and Weight
|
Nominal Conductor Area |
Strand Size |
Insulation Thickness |
Earth Conductor |
Pilot Conductor |
Thickness of Sheath Including SC PCP Layer |
Nominal Overall Diameter |
Nominal Weight |
||
|
Strand Size |
Thickness of Covering |
Strand Size |
Thickness of Covering |
||||||
|
mm² |
No/mm |
mm |
No/mm |
mm |
No/mm |
mm |
mm |
mm |
kg/100m |
|
Type 275 |
|
|
|
|
|
|
|
|
|
|
16 |
126/0.40 |
1.6 |
60/0.30 |
1.0 |
24/0.20 |
0.8 |
3.8 |
30.2 |
145 |
|
25 |
209/0.40 |
1.6 |
100/0.30 |
1.0 |
24/0.20 |
0.8 |
4.0 |
33.9 |
204 |
|
35 |
285/0.40 |
1.6 |
140/0.30 |
1.0 |
24/0.20 |
0.8 |
4.3 |
37.9 |
270 |
|
50 |
380/0.40 |
1.7 |
99/0.40 |
1.0 |
40/0.20 |
0.8 |
4.7 |
41.6 |
333 |